User Manual

5
BASIC ACTIVATION
#2: Basic activation
1. Turn the cover counter-clockwise and open it.
2. Remove the battery blocker.
3. Flood Sensor will conrm being powered with a short beep and a
LED blink.
4. Add the device (see Adding/removing the device on page 6).
5. Close the cover and turn it clockwise.
6. Place the sensor on a surface prone to ooding. Three electrodes
underneath the device should evenly touch the surface.
B
e
e
p!
NOTE
After completing
installation it is rec-
ommended to test
sensors operation
by placing the entire
sensor or its probes
extension wire onto
water surface.
i
NOTE
When changing the
Sensors location, it’s
recommended to wake
up the device and re-
congure the Z-Wave
network by triple click-
ing the TMP button or
removing and insert-
ing the battery.
i
NOTE
When powered, the
device will indicate
Z-Wave status with
colour of LED:
• Green - the device is
already added to the
Z-Wave network.
• Red - the device is
not added to any
Z-Wave network.
i