User Manual

17
ADVANCED PARAMETERS
63. Temperature indication using LED visual indicator
Parameter determines visual indicators operation. Setting to 0 turns
the temperature LED indication o, saving battery life.
Available settings: 0 - visual indicator does not indicate the
temperature
1 - visual indicator indicates the temperature
(blink) every Temperature Measurement Inter-
val (parameter 10, constant current and bat-
tery) and Wake Up Interval (battery mode)
2 - visual indicator indicates the temperature
continuously, only in constant power mode
Default setting: 2 Parameter size: 1 [byte]
73. Temperature measurement compensation
Parameter stores a temperature value to be added to or deducted
from the current temperature measured by internal temperature sen-
sor in order to compensate the dierence between air temperature
and temperature at the oor level.
Available settings: -10 000 to +10 000
Default setting: 0 (0.00°C) Parameter size: 2 [bytes]
74. Alarm frame sent to 1st and 4th Association Group activation
(MOVEMENT_TAMPER / BUTTON_TAMPER)
The device is able to report tamper alarms resulting from sensor’s
tilt/movement or TMP button state change (e.g. taking o the top
cover).
Available settings: 0 - tamper alarms inactive
1 - button tamper alarm active
2 - movement tamper alarm active
3 - button and movement tampers alarm active
Default setting: 2 Parameter size: 1 [byte]
75. Alarms signalization duration
The device is capable of automatically turning o alarm signalization
after a certain amount of time. Long lasting alarm may reduce battery
life, when constantly signalized.
The parameter determines time after which alarm will become quiet
- still active but the device will go into battery saving mode. Visual or
acoustic alarm will be reactivated after time specied in the parameter
76. When alarm status ceases, alarm will be turned o immediately.
Available settings: 0 - alarms active indenitely
1-65535 - time in seconds
Default setting: 0 Parameter size: 4 [bytes]
NOTE
Parameter 75 is ig-
nored when parame-
ter 2 is set to 0.
i