ADVANCED PARAMETERS
#9: Advanced parameters
1. Alarm cancellation delay
Determines time period (in seconds) by which a Flood Sensor will re-
tain the ood state after the ooding itself has ceased. The sensor
will keep on reporting ooding to the main controller. This parameter
setting does not aect acoustic and visual alarms, which turn o im-
mediately after ooding ceases.
Available settings: 0-3600 (in seconds, each 1s)
Default setting: 0 Parameter size: 2 [bytes]
2. Acoustic and visual signals On / O in case of ooding
The parameter allows for deactivation visual and acoustic alarm.
Parameter allows for increasing a battery life. Setting changes will not
aect the sensors communication with the main controller - com-
mands to association groups, alarms and reports will still be sent.
The Flood Sensor allows to customize its operation to user’s needs.
The settings are available in the FIBARO interface as simple options
that may be chosen by selecting the appropriate box.
In order to congure the Flood Sensor (using the FIBARO Home
Center controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced tab.
Wake up interval (battery mode)
Available settings: 0 or 60-86400 (in seconds, 1min - 24h)
Default setting: 21 600 (every 6 hours)
The Flood Sensor will wake up at each dened time interval and al-
ways try to connect with the main controller. After successful com-
munication attempt, the sensor will update conguration parame-
ters, associations and settings and then will go into standby mode.
After failed communication attempt (eg. no Z-Wave range) the device
will go into standby mode and retry to establish connection with the
main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake Up notication
to the controller automatically. Wake up may be still performed man-
ually by a single TMP button click.
Longer time interval means less frequent communication and thus a
longer battery life