ADVANCED PARAMETERS
63. Temperature indication using LED visual indicator
Parameter determines visual indicator’s operation. Setting to 0 turns
the temperature LED indication o, saving battery life.
Available settings: 0 - visual indicator does not indicate the
temperature
1 - visual indicator indicates the temperature
(blink) every Temperature Measurement Inter-
val (parameter 10, constant current and bat-
tery) and Wake Up Interval (battery mode)
2 - visual indicator indicates the temperature
continuously, only in constant power mode
Default setting: 2 Parameter size: 1 [byte]
73. Temperature measurement compensation
Parameter stores a temperature value to be added to or deducted
from the current temperature measured by internal temperature sen-
sor in order to compensate the dierence between air temperature
and temperature at the oor level.
Available settings: -10 000 to +10 000
Default setting: 0 (0.00°C) Parameter size: 2 [bytes]
74. Alarm frame sent to 1st and 4th Association Group activation
(MOVEMENT_TAMPER / BUTTON_TAMPER)
The device is able to report tamper alarms resulting from sensor’s
tilt/movement or TMP button state change (e.g. taking o the top
cover).
Available settings: 0 - tamper alarms inactive
1 - button tamper alarm active
2 - movement tamper alarm active
3 - button and movement tampers alarm active
Default setting: 2 Parameter size: 1 [byte]
75. Alarms signalization duration
The device is capable of automatically turning o alarm signalization
after a certain amount of time. Long lasting alarm may reduce battery
life, when constantly signalized.
The parameter determines time after which alarm will become “quiet”
- still active but the device will go into battery saving mode. Visual or
acoustic alarm will be reactivated after time specied in the parameter
76. When alarm status ceases, alarm will be turned o immediately.
Available settings: 0 - alarms active indenitely
1-65535 - time in seconds
Default setting: 0 Parameter size: 4 [bytes]
NOTE
Parameter 75 is ig-
nored when parame-
ter 2 is set to 0.