Operating Manual

15
ADVANCED PARAMETERS
Available settings: 0 - acoustic and visual alarms inactive
1 - acoustic alarm inactive, visual alarm active
2 - acoustic alarm active, visual alarm inactive
3 - acoustic and visual alarms active
Default setting: 3 Parameter size: 1 [byte]
7.
Requested dimming level / roller blind opening level when send-
ing turn on / open command to 2nd association group devices
Determines the requested on” level to be sent to devices from 2nd
association group upon ood event.
Available settings: 1-99 - requested level
255 - turn a device on
Default setting: 255 Parameter size: 2 [bytes]
9. Deactivate turning o devices in 2nd association group & alarm
cancellation in 3rd group
This setting decides whether device turn o commands and alarm
cancellation notications will be sent to devices in 2nd and 3rd asso-
ciation groups (respectively)
Setting the parameters value to 0 disables sending these two com-
mands to associated devices. This means that these devices WILL NOT
be informed when the ooding has ceased. It is still possible to cancel
alarms in 3rd association group by choosing second (green) menu
position (see “Menu & visual indications” on page 10).
Available settings: 0 - alarm (ooding) cancellation inactive
1 - alarm (ooding) cancellation active
Default setting: 1 Parameter size: 1 [byte]
10. Temperature measurement interval
Time interval (in seconds) between consecutive measurements of
battery level and temperature (done by built-in temperature sensor).
If the temperature diers from previously reported by a value deter-
mined in parameter 12, it will be reported to the Z-Wave controller.
In battery mode more signicant battery level changes will be report-
ed. Short time intervals mean more frequent communication, which
results in shortened battery life.
After consecutive FAILED and SUCCESSFUL communication attempts,
the Sensor will go to standby mode.
Available settings: 1-65535 (in seconds)
Default setting: 300 (5min) Parameter size: 4 [bytes]
12. Temperature measurement hysteresis
Determines a minimum temperature change value (insensitivity lev-
el), resulting in a temperature report being sent to the main control-