Operating Manual

11
OPERATING THE DEVICE
NOTE
Resetting the device is
not the recommend-
ed way of removing
the device from the
Z-Wave network. Use
reset procedure only
if the primary con-
troller is missing or
inoperable. Certain
device removal can be
achieved by the pro-
cedure of removing
described in “Adding/
removing the device”
on page 6.
i
Resetting the Flood Sensor:
Reset procedure allows to restore the device back to its factory set-
tings, which means all information about the Z-Wave controller and
user conguration will be deleted.
1. Make sure the sensor is powered.
2. Press and hold the TMP button.
3. Wait for the visual LED indicator to glow yellow (4th position of
the MENU).
4. Release the TMP button.
5. Click the TMP button once to conrm selection.
6. After few seconds the device will restart with factory settings,
which is signalled with the red visual indicator colour and
an acoustic signal.
Waking up the Flood Sensor:
When in battery mode the Flood Sensor needs to be woken up to
receive information about the new conguration from the controller,
like parameters and associations.
To wake up the sensor manually, click the TMP button located inside
the housing.
The device will also wake up and update its data upon startup when
added in battery mode.
Menu allows to perform Z-Wave network actions. In order to use the
menu:
1. Press and hold the TMP button.
2. Wait for the device to indicate desired position with a colour:
• WHITE - conrmation of entering the menu
• GREEN - cancel alarm for associated devices and the control-
ler (only if the device is no longer ooded)
• VIOLET - Z-Wave network’s range test
• YELLOW - full reset
3. Release the TMP button.
4. Click the TMP button to conrm selection.