User's Manual

9
OPERATING THE DEVICE
#5: Operating the device
Controlling the Switch 2 using a momentary switch
and parameter 20 set to 0:
1x click:
Change the state of the connected load to the opposite one
(S1 switches 1st channel, S2 switches 2nd channel),
Change the state of 2nd, 3rd (S1 switch), 4th and 5th (S2 switch)
association group to the opposite one.
2x click:
Set maximum level of devices associated in 2nd, 3rd (S1 switch),
4th and 5th (S2 switch) group.
Hold:
Start smooth control of devices associated in 3rd (S1 switch) and
5th (S2 switch) group.
Release:
Stop smooth control of devices associated in 3rd (S1 switch) and
5th (S2 switch) group.
NOTE
Momentary switch
After releasing the
switch a spring auto-
matically pushes back
and disconnects the
switch)
Toggle switch
Operates as a two-po-
sition switch, it has no
spring that would set
one position of the
switch.
i
Controlling the Switch 2 using a toggle switch and parameter 20
set to 1:
Close switch contact:
Turn ON the connected load (S1 switches 1st channel, S2 switches
2nd channel),
Turn ON devices associated in 2nd, 3rd (S1 switch), 4th and 5th
(S2 switch) group.
Open switch contact:
Turn OFF the connected load (S1switches 1st channel, S2switches
2nd channel).
Turn OFF devices associated in 2nd, 3rd (S1 switch), 4th and 5th
(S2 switch) group.
Controlling the Switch 2 using a toggle switch and parameter 20
set to 2:
Change switch position once:
Change the state of the connected load to the opposite one
(S1 switches 1st channel, S2 switches 2nd channel),
Change the state of 2nd, 3rd (S1 switch), 4th and 5th (S2 switch)
association group to the opposite one.
Change switch position twice:
Set maximum level of devices associated in 2nd, 3rd (S1 switch),
4th and 5th (S2 switch) group.
NOTE
Toggle switch and
parameter 20 set to 1:
State of the device
is synchronized with
state of the external
toggle switches.
Toggle switch and
parameter 20 set to 2:
State of the device is
reversed with every
change in state of
the external toggle
switch.
i