User's Manual
21
ADVANCED PARAMETERS
41. Reaction to Flood Alarm
This parameter determines how the device will react to Flood Alarm
frame.
Available settings: 0 - alarm frame is ignored
1 - turn ON after receiving the alarm frame
2 - turn OFF after receiving the alarm frame
3 - ash after receiving the alarm frame
Default setting: 2 Parameter size: 1 [byte]
42. Reaction to CO/CO2/Smoke Alarm
This parameter determines how the device will react to CO, CO2 or
Smoke frame.
Available settings: 0 - alarm frame is ignored
1 - turn ON after receiving the alarm frame
2 - turn OFF after receiving the alarm frame
3 - ash after receiving the alarm frame
Default setting: 3 Parameter size: 1 [byte]
43. Reaction to Heat Alarm
This parameter determines how the device will react to Heat Alarm
frame.
Available settings: 0 - alarm frame is ignored
1 - turn ON after receiving the alarm frame
2 - turn OFF after receiving the alarm frame
3 - ash after receiving the alarm frame
Default setting: 1 Parameter size: 1 [byte]
44. Flashing alarm duration
This parameter allows to set duration of ashing alarm mode.
Available settings: 1-32000 (1-32000s, 1s step) - duration
Default setting: 600 (10min) Parameter size: 2 [bytes]
50. First channel - power reports
This parameter determines the minimum change in consumed power
that will result in sending new power report to the main controller.
Available settings: 0 - reports are disabled
1-100 (1-100%) - change in power
Default setting: 20 (20%) Parameter size: 1 [byte]