User's Manual
20
ADVANCED PARAMETERS
35. S2 switch - associations sent to 4th and 5th association groups
This parameter determines which actions result in sending com-
mands to devices associated in 4th and 5th association group.
All actions are active by default.
Available settings: 1 - ignore turning on with 1 click of the switch
2 - ignore turning o with 1 click of the switch
4 - ignore holding and releasing the switch*
8 - ignore double click of the switch**
Default setting: 0 Parameter size: 1 [byte]
36. S2 switch - Switch ON value sent to 4th and 5th association
groups
This parameter denes value sent with Switch ON command to devic-
es associated in 4th and 5th association group.
Available settings: 0-255 - sent value
Default setting: 255 Parameter size: 2 [bytes]
37. S2 switch - Switch OFF value sent to 4th and 5th association
groups
This parameter denes value sent with Switch OFF command to de-
vices associated in 4th and 5th association group.
Available settings: 0-255 - sent value
Default setting: 0 Parameter size: 2 [bytes]
38. S2 switch - Double Click value sent to 4th and 5th association
groups
This parameter denes value sent with Double Click command to de-
vices associated in 4th and 5th association group.
Available settings: 0-255 - sent value
Default setting: 99 Parameter size: 2 [bytes]
40. Reaction to General Alarm
This parameter determines how the device will react to General Alarm
frame.
Available settings: 0 - alarm frame is ignored
1 - turn ON after receiving the alarm frame
2 - turn OFF after receiving the alarm frame
3 - ash after receiving the alarm frame
Default setting: 3 Parameter size: 1 [byte]
NOTE
Parameter 35 values
may be combined, e.g.
1+2=3 means that as-
sociations for turning
ON and OFF are not
sent.
i
NOTE
*Hold and release is
inactive when param-
eter 20 is set to 1 or 2.
**Double click is inac-
tive when parameter
20 is set to 1.
i