User's Manual

18
ADVANCED PARAMETERS
18. Second channel - pulse time for ashing mode (only FGS-223)
This parameter allows to set time of switching to opposite state in
ashing mode.
Available settings: 1-32000 (0.1-3200.0s, 0.1s step) - time param-
eter
Default setting: 5 (0.5s) Parameter size: 2 [bytes]
20. Switch type
This parameter denes as what type the device should treat the
switch connected to the S1 and S2 terminals.
Available settings: 0 - momentary switch
1 - toggle switch (contact closed - ON, contact
opened - OFF)
2 - toggle switch (device changes status when
switch changes status)
Default setting: 2 Parameter size: 1 [byte]
21. Flashing mode - reports
This parameter allows to dene if the device sends reports during the
ashing mode.
Available settings: 0 - the device does not send reports
1 - the device sends reports
Default setting: 0 Parameter size: 1 [byte]
27. Associations in Z-Wave network security mode
This parameter denes how commands are sent in specied asso-
ciation groups: as secure or non-secure. Parameter is active only in
Z-Wave network security mode. This parameter does not apply to 1st
„Lifeline group.
Available settings: 1 - 2nd group sent as secure
2 - 3rd group sent as secure
4 - 4th group sent as secure
8 - 5th group sent as secure
Default setting: 15 (all) Parameter size: 1 [byte]
28. S1 switch - scenes sent
This parameter determines which actions result in sending scene IDs
assigned to them.
Available settings: 1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key Hold Down and Key Released
Default setting: 0 Parameter size: 1 [byte]
NOTE
Parameter 27 values
may be combined,
e.g. 1+2=3 means that
2nd & 3rd groups are
sent as secure.
i
NOTE
Parameter 28 values
may be combined,
e.g. 1+2=3 means that
scenes for single and
double click are sent.