User's Manual

17
ADVANCED PARAMETERS
12. First channel - time parameter for delay/auto ON/OFF modes
This parameter allows to set time parameter used in timed modes.
Available settings: 0 (0.1s), 1-32000 (1-32000s, 1s step) - time
parameter
Default setting: 50 (50s) Parameter size: 2 [bytes]
13. First channel - pulse time for ashing mode
This parameter allows to set time of switching to opposite state in
ashing mode.
Available settings: 1-32000 (0.1-3200.0s, 0.1s step) - time param-
eter
Default setting: 5 (0.5s) Parameter size: 2 [bytes]
15. Second channel - operating mode (FGS-223 only)
This parameter allows to choose operating for the 1st channel con-
trolled by the S2 switch.
Available settings: 0 - standard operation
1 - delay ON
2 - delay OFF
3 - auto ON
4 - auto OFF
5 - ashing mode
Default setting: 0 Parameter size: 1 [byte]
16. Second channel - reaction to switch for delay/auto ON/OFF
modes (FGS-223 only)
This parameter determines how the device in timed mode reacts to
pushing the switch connected to the S2 terminal.
Available settings: 0 - cancel mode and set target state
1 - no reaction to switch - mode runs until it ends
2 - reset timer - start counting from the beginning
Default setting: 0 Parameter size: 1 [byte]
17. Second channel - time parameter for delay/auto ON/OFF
modes (FGS-223 only)
This parameter allows to set time parameter used in timed modes.
Available settings: 0 (0.1s), 1-32000 (1-32000s, 1s step) - time
parameter
Default setting: 50 (50s) Parameter size: 2 [bytes]