User Manual

10
SEQUENCES
#7: Sequences
Sequences:
User can create sequences of two to ve button to expand number
of possible actions. Every sequence sends corresponding Scene ID to
the Z-Wave controller with attribute "Key pressed 1 time" (see "Scene
activation" on page 11).
Sequences are saved in advanced parameters (no. 3-8).
Activating sequence introduces delay in single, double and tripple
press actions for rst button in the sequence.
Rules of creating sequences:
Maximum of six sequences can be created.
Each sequence must be unique.
Sequence can consist of two to ve button pushes.
Sequence can contain multiple presses of the same button.
Setting a new sequence using advanced parameter:
1. Calculate value of parameter using table and formula:
Value of parameter = Value of rst button +
+ 8 * Value of second button + 64 * Value of third button +
+ 512 * Value of third button + 4096 * Value of third button
2. Change the value of corresponding parameter [2 bytes] (parame-
ters 3 to 8 for slots 1 to 6).
3. Press
and simultaneously to wake up the device.
4. Wait for the device to congure.
Button
Value 1 2 3 4 5 6
Setting a new sequence using Home Center conguration
interface:
1. Go to the device options by clicking the icon:
2. Clicking Add a new sequence.
3. Select sequence of 2 to 5 buttons.
4. Select reaction to sequence.
5. Save conguration.
6. Press
and simultaneously to wake up the device.
7. Wait for the device to congure.