User Manual
17
ADVANCED PARAMETERS
10. Single button associations - operating mode
This parameter allows to choose operating mode for single button
associations.
Available settings: 0 - single press switches state to opposite
1 - single press switches state to opposite, dou-
ble press sets to maximum level
2 - single press turns on, double press turns o
Default setting: 0
(switch)
Parameter size: 1 [byte]
11. Value sent to association group
12. Value sent to
association group
13. Value sent to
association group
14. Value sent to
association group
15. Value sent to
association group
16. Value sent to
association group
This parameter allows to set value sent to devices in association
group. It will result in turning multilevel devices on with set or last
level. Value is irrelevant for simple on/o devices.
Available settings: 1-99 or 255
Default setting: 255 Parameter size: 2 [bytes]
17. Paired buttons association for
and
This parameter allows to activate paired buttons association mode
for
and buttons. Paired buttons are dependent and association
are sent only to
groups. turns devices on and increases value,
turns them o and decreases value.
Available settings: 0 - paired buttons association inactive
1 - paired buttons association active
Default setting: 0 (inactive) Parameter size: 1 [byte]
18. Paired buttons association for
and
This parameter allows to activate paired buttons association mode
for
and buttons. Paired buttons are dependent and association
are sent only to
groups. turns devices on and increases value,
turns them o and decreases value.
Available settings: 0 - paired buttons association inactive
1 - paired buttons association active
Default setting: 0 (inactive) Parameter size: 1 [byte]
NOTE
Setting parameters
11-16 to appropriate
value will result in:
1-99 - forcing level of
associated devices
255 - setting associat-
ed devices to the last
remembered state or
turning them on
i