User's Manual

16
ADVANCED PARAMETERS
50. Interval of temperature measurements
This parameter denes how often the temperature will be measured.
The shorter the time, the more frequently the temperature will be
measured, but the battery life will shorten.
Available settings: 0 - temperature measurements disabled
5-32400 - time in seconds
Default setting: 300 (5min) Parameter size: 2 [bytes]
51. Temperature reports threshold
This parameter denes the change of temperature in comparison with last
reported, resulting in temperature report being sent to the main controller.
Available settings:
0 - temperature reports based on threshold disabled
1-300 - temperature threshold (0.1-30°C, 0.1°C step)
Default setting: 10 (1
°C )
Parameter size: 2 [bytes]
52. Interval of temperature reports
This parameter determines how often the temperature reports will be
sent to the main controller.
Available settings: 0 - periodic temperature reports disabled
5-32400 - time in seconds
Default setting: 0 Parameter size: 2 [bytes]
53. Temperature oset
The value to be added to the actual temperature, measured by the sen-
sor (temperature compensation).
Available settings: -1000-1000 (-100-100°C, 0.1°C step)
Default setting: 0 (0
°C )
Parameter size: 4 [bytes]
54. Temperature alarm reports
Temperature alarms reported to the Z-Wave controller. Thresholds are
set in parameters 55 and 56.
Available settings: 0 - temperature alarms disabled
1 - high temperature alarm
2 - low temperature alarm
3 - high and low temperature alarms enabled
Default setting: 0 Parameter size: 1 [byte]
55. High temperature alarm threshold
If temperature is higher than set value, overheat notication will be
sent and high temperature scene will be triggered (if activated).
Available settings: 0-1000 (0-100°C, 0.1°C step)
Default setting: 540 (54°) Parameter size: 2 [bytes]
NOTE
Parameter 51 is active
only if parameter 50 is
not set to 0.
i
NOTE
Temperature meas-
urement is performed
before sending any
report (regardless of
parameter no. 50). Ex-
cessive reporting can
aect battery lifetime.
Reporting on the ba-
sis of temperature
change (parameter
no. 51) is recommend-
ed.
i