50. Interval of temperature measurements
This parameter denes how often the temperature will be measured.
The shorter the time, the more frequently the temperature will be
measured, but the battery life will shorten.
Available settings: 0 - temperature measurements disabled
5-32400 - time in seconds
Default setting: 300 (5min) Parameter size: 2 [bytes]
51. Temperature reports threshold
This parameter denes the change of temperature in comparison with last
reported, resulting in temperature report being sent to the main controller.
Available settings:
0 - temperature reports based on threshold disabled
1-300 - temperature threshold (0.1-30°C, 0.1°C step)
Default setting: 10 (1
°C )
Parameter size: 2 [bytes]
52. Interval of temperature reports
This parameter determines how often the temperature reports will be
sent to the main controller.
Available settings: 0 - periodic temperature reports disabled
5-32400 - time in seconds
Default setting: 0 Parameter size: 2 [bytes]
53. Temperature oset
The value to be added to the actual temperature, measured by the sen-
sor (temperature compensation).
Available settings: -1000-1000 (-100-100°C, 0.1°C step)
Default setting: 0 (0
°C )
Parameter size: 4 [bytes]
54. Temperature alarm reports
Temperature alarms reported to the Z-Wave controller. Thresholds are
set in parameters 55 and 56.
Available settings: 0 - temperature alarms disabled
1 - high temperature alarm
2 - low temperature alarm
3 - high and low temperature alarms enabled
Default setting: 0 Parameter size: 1 [byte]
55. High temperature alarm threshold
If temperature is higher than set value, overheat notication will be
sent and high temperature scene will be triggered (if activated).
Available settings: 0-1000 (0-100°C, 0.1°C step)
Default setting: 540 (54°) Parameter size: 2 [bytes]
NOTE
Parameter 51 is active
only if parameter 50 is
not set to 0.
i
NOTE
Temperature meas-
urement is performed
before sending any
report (regardless of
parameter no. 50). Ex-
cessive reporting can
aect battery lifetime.
Reporting on the ba-
sis of temperature
change (parameter
no. 51) is recommend-
ed.
i