INSTALLATION
#4: Installation
Connecting the FIBARO Dimmer 2 in a manner inconsistent
with manual may cause risk to health, life or material
damage.
When connecting FIBARO Dimmer 2 act in accordance with the
following rules:
• Connect only in accordance with one of the diagrams
• Electrical installation must be protected by overcurrent protection
(fuse) of with a value not higher than 10A
• Dimmer 2 should be installed in a wall switch box compliant with a
relevant national safety standards and with depth no less than 2.4
inches (60 mm)
• Electrical switches used in installation should be compliant with the
relevant safety standards
• Length of wires used to connect the control switch should not
exceed 65 ft (20 m)
!
Installation of the FIBARO Dimmer 2:
1. Switch o the mains voltage (disable the fuse)
2. Open the wall switch box
3. Connect with one of the following diagrams:
B
DIMMER
Notes for the diagrams:
L - terminal for live lead
S1 - terminal for switch no. 1 (has the option of
entering the device in learning mode)
S2 - terminal for switch no. 2
Sx - terminal for power supply to the switch con-
nected to the Dimmer 2
N - terminal for neutral lead
- output terminal of the Dimmer 2 (controlling
connected light source)
B - service button (used to add/remove the device
and navigate the menu)