User's Manual

8
INSTALLATION
#4: Installation
Connecting the FIBARO Dimmer 2 in a manner inconsistent
with manual may cause risk to health, life or material
damage.
When connecting FIBARO Dimmer 2 act in accordance with the
following rules:
Connect only in accordance with one of the diagrams
Electrical installation must be protected by overcurrent protection
(fuse) of with a value not higher than 10A
Dimmer 2 should be installed in a wall switch box compliant with a
relevant national safety standards and with depth no less than 2.4
inches (60 mm)
Electrical switches used in installation should be compliant with the
relevant safety standards
Length of wires used to connect the control switch should not
exceed 65 ft (20 m)
!
Installation of the FIBARO Dimmer 2:
1. Switch o the mains voltage (disable the fuse)
2. Open the wall switch box
3. Connect with one of the following diagrams:
B
DIMMER
Notes for the diagrams:
L - terminal for live lead
S1 - terminal for switch no. 1 (has the option of
entering the device in learning mode)
S2 - terminal for switch no. 2
Sx - terminal for power supply to the switch con-
nected to the Dimmer 2
N - terminal for neutral lead
- output terminal of the Dimmer 2 (controlling
connected light source)
B - service button (used to add/remove the device
and navigate the menu)