User's Manual

32
ADVANCED PARAMETERS
53. Energy reports
Energy level change which will result in sending a new energy report.
Available settings: 0 - energy reports disabled
1-255 (0.01-2.55 kWh) - report triggering threshold
Default setting: 10 (0.1 kWh) Parameter size: 2 [bytes]
54. Self-measurement
The Dimmer 2 may include active power and energy consumed by
itself in reports sent to the main controller.
Available settings: 0 - Self-measurement inactive
1 - Self-measurement active
Default setting: 0 Parameter size: 1 [byte]
58. Method of calculating the active power
This parameter denes how to calculate active power. It is useful in a
case of 2-wire connection with light sources other than resistive.
Available settings: 0 - measurement based on the standard algorithm
1 - approximation based on the calibration data
2 - approximation based on the control angle
Default setting: 0 Parameter size: 1 [byte]
59. Approximated power at the maximum brightness level
This parameter determines the approximate value of the power that
will be reported by the device at its maximum brightness level.
Available settings: 0-500 (0-500W) - power consumed by the load
at the maximum brightness level.
Default setting: 0 Parameter size: 2 [bytes]
NOTE
Parameter 58 is set
to 0 after forced au-
to-calibration.
i
NOTE
Parameter 59 works
only when parameter
58 has a value other
than 0.
i