User's Manual
27
ADVANCED PARAMETERS
Available settings: 0 - all groups (II-V) sent as non-secure
1 - 2nd group sent as secure
2 - 3rd group sent as secure
4 - 4th group sent as secure
8 - 5th group sent as secure
15 - all groups (II-V) sent as secure
Default setting: 15 Parameter size: 1 [byte]
28. Scene activation functionality
SCENE ID depends on the switch type congurations.
Available settings: 0 - functionality deactivated
1 - functionality activated
Default setting: 0 Parameter size: 1 [byte]
SCENE ID value sent at specied conguration:
Momentary switches
SCENE ID: S1 input SCENE ID: S2 input
16 : 1 x click
14 : 2 x click
- : 3 x click
12 : hold
13 : release
26 : 1 x click
24 : 2 x click
25 : 3 x click
22 : hold
23 : release
Toggle switches
SCENE ID: S1 input SCENE ID: S2 input
10 : OFF to ON
11 : ON to OFF
14 : 2 x click
- : 3 x click
20 : OFF to ON
21 : ON to OFF
24 : 2 x click
25 : 3 x click
Roller blinds switches
SCENE ID: S1 input SCENE ID: S2 input
10 : turn ON (1 x click)
13 : release
14 : 2 x click
- : 3 x click
17 : brightening
11 : turn OFF (1 x click)
13 : release
14 : 2 x click
15 : 3 x click
18 : dimming
29. Switch functionality of S1 and S2
This parameter allows for switching the role of keys connected to S1
and S2 without changes in connection.
Available settings: 0 - standard mode
1 - S1 operates as S2, S2 operates as S1
Default setting: 0 Parameter size: 1 [byte]
NOTE
Enabling scene activa-
tion functionality may
cause slight delay in
response to external
switches and sending
associations.
i
NOTE
Parameter 27 values
may be combined,
e.g. 1+2=3 means that
2nd & 3rd group are
sent as secure.
i