ADVANCED PARAMETERS
11. ALL ON/ALL OFF function
Parameter allows for activation/deactivation of Z-Wave commands
enabling/disabling all devices located in direct range of the main
controller.
Available settings: 0 - ALL ON not active, ALL OFF not active
1 - ALL ON not active, ALL OFF active
2 - ALL ON active, ALL OFF not active
255 - ALL ON active, ALL OFF active
Default setting: 255 Parameter size: 2 [bytes]
13. Force auto-calibration
Changing value of this parameter will force the calibration process.
During the calibration parameter is set to 1 or 2 and switched to 0
upon completion.
Available settings: 0 - readout
1 - force auto-calibration of the load without
FIBARO Bypass 2
2 - force auto-calibration of the load with
FIBARO Bypass 2
Default setting: 0 Parameter size: 1 [byte]
14. Auto-calibration status (read-only parameter)
This parameter determines operating mode of the Dimmer 2 (auto-
matic/manual settings).
Available settings: 0 - calibration procedure not performed or Dim-
mer 2 operates on manual settings
1 - Dimmer 2 operates on auto-calibration settings
Default setting: 0 Parameter size: 1 [byte]
15. Burnt out bulb detection
Function based on the sudden power variation of a specic value, in-
terpreted as a LOAD ERROR.
Available settings: 0 - function disabled
1-99 - percentage value of power variation,
compared to standard power consumption,
measured during the calibration procedure (to
be interpreted as load error/burnt out bulb)
Default setting: 30 Parameter size: 1 [byte]
16. Time delay of a burnt out bulb (parameter 15) or overload (pa-
rameter 39) detection
Time of delay (in seconds) for power variation detection, interpreted
as a LOAD ERROR or OVERLOAD detection (too much power connect-
ed to the Dimmer 2).
CAUTION
Parameter 15 is rele-
vant only when pa-
rameter 58 is set to 0
and the control mode
is consistent with the
mode set during the
calibration process
(parameter 30).
!