User's Manual

10
INSTALLATION
4. After verifying correctness of connection switch on the mains
voltage
5. Wait around 30s for the calibration process to end (see „Calibra-
tion on page 15), light may blink during the process
6. After successful calibration the device will be turned o by default
7. Add the device to the Z-Wave network (see „Adding/removing the
device on page 11)
8. Turn o the mains voltage, then arrange the device and its anten-
na in a wall switch box
9. Close the wall switch box and turn on the mains voltage
B
DIMMER
Wiring diagram no. 5 - momentary wall switches
connection
NOTE
It is not recommend-
ed to install dierent
types of wall switches
(momentary, toggle,
etc.) in a 3-way con-
nection.
i
Wiring diagram no. 4 - 3-way switch connection
B
DIMMER
1 3
P
13
P2
1 3
P
Tips for arranging the antenna:
Locate the antenna as far from metal elements as possible
(connecting wires, bracket rings, etc.) in order to prevent
interferences.
Metal surfaces in the direct vicinity of the antenna (e.g. ush
mounted metal boxes, metal door frames) may impair signal
reception!
Do not cut or shorten the antenna - its length is perfectly matched
to the band in which the system operates.
NOTE
After switching on the
mains voltage LED
indicator will signal
Z-Wave network in-
clusion state with a
colour:
GREEN - device added
RED - device not added
RED/GREEN ALTER-
NATELY- Z-Wave error
i