Weatherproof telephone FernTel 3 Version 21 keys with display Version 16 keys without display Version without keys, without display Tabletop unit Operating manual FHF BA 9620 03/09
Note Please read the operating manual carefully before installing the device. Please check the contents of the box for completeness. Table of Contents General operating notes.................................................................................... 4 Device overview / Dimensions ........................................................................ 5 Device versions .................................................................................................... 5 Controls and indicators ...
Total lock ......................................................................................... 16 Telephone book ............................................................................... 16 Programming.................................................................................... 16 Direct call number .................................................................................. 16 PIN ......................................................................................................
General operating notes 1. The versions of FernTel 3 can be operated in the analogue, public telephone network and connected to analogue terminals of branch exchanges. 2. The receiver is equipped with a leakage field spool for coupling of hearing aids. Users of a hearing aid with inductive receiver may receive the signal from the receiver inset directly. 3. The version without keypad does not offer you all the performance features available in other versions. 4.
Device overview / Dimensions (mm / inch) Device versions The telephone FernTel 3 is available in three versions.
Controls and indicators Version with keypad (21 keys) and display Keypad Menu operations keys Short / Speed code dialling Disconnect Last number redial Enquiry key ________________________ Number keys Display The two uppermost lines display numbers or the menu settings. The lower line displays pictograms that correspond to the functions.
Version with keypad (16 keys), without display Keypad Amplified listening in receiver Disconnect Last number redial Enquiry key ________________________ Number keys Version without keypad, without display Device-internal programming keypad (12 keys) 1 2 3 4 5 6 7 8 9 * 0 # 7
As-delivered condition Box contents The scope of the delivery includes: - 1 telephone - 1 telephone mount - 1 handset accommodation for the table version with 2 screws - 4 washers Ø 18 mm - this operating manual Telephone presetting Valid for version Dialling mode Enquiry key function (R key) Exchange code Pause following exchange code Last number redial memory Speed code dialling memory Short code dialling memory Mode A key Direct call memory Restrictions Amplified listening in receiver PIN Ringing melod
Mounting and installing Wall version Fasten the telephone mount with 4 screws (2). Place the provided washers Ø 18 mm under the screw head. Bore illustration (not to scale) Place the telephone in the upper latches (A), swing it downwards until the lower latches audibly engage (B). Remove the keypad plate (6), and tighten the two locking screws (3) as far as they will go. Important: This preserves the IP65 degree of protection.
Plug the ribbon cable onto the pin contact strip (7) of the keypad plate. Tighten the keypad plate (6) using four screws (8). Table version Place the telephone in the lower latches (A), swing it backwards until the upper latches audibly engage (B). Pull the telephone line through the cable gland (4) and connect it with terminal (5) TCP/La TCP/Lb. Use cables with a sheath diameter of 5 to 9 mm only, otherwise the IP65 degree of protection can not be guaranteed.
Mounting the sling holder (optional) Remove the keypad plate (6) by loosening the screws (8). Lever out the duct cover (13). Fasten the sling holder (14) by using the two included screws (15). Insert the duct cover (16) with groove. Screw the keypad plate (6) back on again. Connection of a secondary sounder If you want the telephone to control a secondary sounder, the blind plug must be replaced by a cable gland M20x1.5 IP65.
Operation and programming Version with keypad (21 keys) and display Operation Seize (Make / answer a call) When you pick up the handset, you may answer a call or make a call to a conversation partner. Receiver volume During a call you can adjust the volume in the receiver for the duration of the call, using the and . If you want to change the receiver volume permanently, please use the keys programming menu „Settings/Receiver volume“ Make a call Dial the desired number by using the number keys.
Programming In order to program the telephone, you have to allow modifications of the settings. General Use the Programming menu to modify the operating settings of the telephone. After lifting the handset or pressing the disconnect key, a welcome message appears in the display. Begin the programming procedure by pressing the key. In the top line of the display, the text „Main menu“ appears. In the second line, you see the first menu item of the Main menu.
- Restrictions Programming SW version Press the key to select a menu item. Telephone book In the telephone book, you press the and keys to display the entered names (and numbers). Press the key to choose between the following sub-menus: - dial modify add delete delete all In case of an empty telephone book, only the sub-menu „add“ appears. For using the menus „add“, „modify“, „delete“, „delete all“, you are also required to enter the PIN.
Settings Under Settings, use the and - Ringing signal - Volume - Dialling mode - PBX - Menu - As-delivered condition - PIN keys to display the following sub-menus: Ringing signal The volume and melody of the ringing signal are set. Volume The receiver volume is set permanently. Dialling mode Here, one of four dialling modes is selected.
Restrictions Under Restrictions, use the - Activate - Direct call number and Activate Choose from - none - Telephone book - Direct call - Total lock keys to display the following sub-menus: The telephone is not restricted. Numbers can be dialled from the telephone book only. When pressed, all keys except the Disconnect key and the key dial the direct call number. The telephone is fully restricted. Calls can be received only.
Version with keypad (16 keys), without display Operation Seize (Make / answer a call) When you pick up the handset, you may answer a call or make a call to a conversation partner. Amplified listening in receiver Press the A key to increase the receiver volume during a call. Depending on the presetting, the volume is increased in one or two steps. Pressing the A key one more time reduces the volume to the previous level. Make a call Dial the desired number by using the number keys.
Restrict settings modifications - Lift the handset. Press the * and # keys simultaneously. Press the # and 1 keys consecutively. Enter the PIN Press the key to disable settings modifications. Replace the handset. (PIN) Adjust ringing volume - Lift the handset. Press the * and # keys simultaneously. Press key 5 (the ringing sound is played back with the selected volume setting). Set the desired volume using the keys 1 to 6. Press the key to store the selected volume. Replace the handset.
Set dialling mode - Lift the handset. Press the * and # keys simultaneously. Press key 9. Enter the code for the desired dialling mode. Press the key to store the selected dialling mode. Replace the handset. Code / Key 1 Dialling mode Dual-tone multifrequency (DTMF), unlimited tone duration Comment 2 Dual-tone multifrequency (DTMF), tone duration 90 ms Pulse dialling (PD), 1.
Program the pause following the exchange code - Lift the handset. Press the * and # keys simultaneously. Press key 1. Press a key from 1 to 5 (the key number corresponds to the duration in seconds) Press the key to store the entered duration of the pause. Replace the handset. (1…5) Program the Enquiry Key (flash time) For dual-tone multifrequency only. Pressing the enquiry key briefly interrupts the loop to the private branch exchange (flash) to enable an enquiry to another private branch connection.
Change Personal Identification Number (PIN) - Lift the handset. Press the * and # keys simultaneously. Press the # and 2 keys consecutively. Enter the old PIN. Enter new PIN. Repeat new PIN. Press the key to store the new PIN. Replace the handset. (old PIN) (new PIN) (new PIN) Signalling tones during programming Tone Number Significance Acknowledgement tone 1 long tone Error tone 4 short tones PIN tone 1 short tone sequence Completion of a correctly performed procedure.
Version without keypad and without display Operation Seize (Make / answer a call) and dialling Receive a call by lifting the handset. If you want to make a call, lift the handset. The private branch exchange then automatically establishes a connection. The telephone is equipped with an internal keypad on the inside of the front plate. You may use this to program a speed code dialling number. When the handset is lifted, this programmed number is then dialled automatically.
Adjust the ringing melody - Lift the handset. Press the * key. Press key 6 (the set melody is played back) Set the desired melody using the keys 1 to 9. Press the # key to store the selected melody. Replace the handset. (1…9) Set dialling mode - Lift the handset. Press the * key. Press key 9. Enter the code for the desired dialling mode. Press the # key to store the selected dialling mode. Replace the handset.
General information Service You have bought a modern FHF product subject to meticulous quality control. If any questions regarding the telephone, or malfunctions should occur – even after the guarantee has expired – please contact FHF. Please have the type denomination and product number (to be found on the nameplate) ready. Care and maintenance The telephone is maintenance-free. Still, if the operating area is highly contaminated by dust, fat, oil etc., the device should be cleaned from time to time.
Technical Data Connection data Supply voltage Supply current Ringing alternating current Ringing frequency Ringer input impedance Enquiry key (flash) Dialling mode DTMF PD 24….66 Vdc 19…100 mA 30….90 Vac 16….68 Hz ≥ 6.0 k Ω at 25 Hz ≥ 3.5 k Ω at 50 Hz only for DTMF 80 ms, 120 ms, 600 ms Frequencies according to ITU-T Q.23 Tone duration unlimited or 90 ms Pulse/Pause ratio 1.5:1 (60/40 ms) or 2:1 (66.7/33.3 ms) Ringing volume max. approx.
EC Declaration of Conformity EMC-Directive The device complies with the requirements of the new EMC-directive 2004/108/EC, the low voltage directive 2006/95/EC and the R&TTE directive 1999/5/EC. The conformity with the above directives is confirmed by the CE sign. If you experience problems during operation, please contact the FHF’s technical support service. Electric and electronic devices carrying this symbol may contain substances harmful to people and the environment.
Subject to alterations or errors FHF Funke + Huster Fernsig GmbH Gewerbeallee 15-19 · D-45478 Mülheim an der Ruhr Phone +49 / 208 / 82 68-0 · Fax +49 / 208 / 82 68-286 http://www.fhf.de · e-mail: info@fhf.