Product Card
Exhaust System
Silencer Type:
Silencer Model & Quantity:
Pressure Drop Across Silencer
System:
kPa (in Hg)
Silencer Noise Reduction Level: dB
Maximum Allowable Back Pressure:
kPa (in Hg)
Exhaust Gas Flow: m³/min (cfm)
Exhaust Gas Temperature: °C (°F)
60 Hz50 Hz
- Prime
- Standby
- Prime
- Standby
Lubrication System
Oil Filter Type:
Total Oil Capacity:
l (US gal)
Oil Pan: l (US gal)
Oil Type:
Oil Cooling Method:
Cooling System
Cooling System Capacity: l (US gal)
Water Pump Type:
Heat Rejected to Water & Lube Oil:
kW (Btu/min)
Heat Radiation to Room: Heat radiated from engine and alternator
kW (Btu/min)
Radiator Fan Load: kW (hp)
Radiator Cooling Airflow: m³/min (cfm)
External Restriction to
Cooling Airflow: Pa (in H
2
O)
Designed to operate in ambient conditions up to 50°C (122°F).
Contact your local FG Wilson Dealer for power ratings at specific site conditions.
60 Hz50 Hz
- Prime
- Standby
- Prime
- Standby
Engine Technical Data Air Systems
No. of Cylinders / Alignment:
Cycle:
Bore / Stroke:
mm (in)
Induction:
Engine Speed: rpm
Performance
Gross Engine Power:
kW (hp)
BMEP: kPa (psi)
Fuel System
Fuel Filter Type:
Recommended Fuel:
Fuel Consumption:
l/hr (US gal/hr)
Prime
50 Hz
60 Hz
110% 100% 75% 50%
Load Load Load Load
60 Hz
50 Hz
Standby Load Load Load Load
50%75%100%110%
(Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,
Class A2)
Air Filter Type:
Combustion Air Flow:
m³/min (cfm)
Max. Combustion Air Intate
Restriction: kPa (in H
2
O)
60 Hz50 Hz
Cooling Method:
Governing Type:
Governing Class:
Compression Ratio:
Displacement:
l (cu. in)
Moment of Inertia: kg m² (lb/in²)
Engine Electrical System:
Weight:
kg (lb)
60 Hz50 Hz
- Standby
- Prime
- Standby
- Prime
- Standby
- Prime
- Dry
- Wet
- Voltage / Ground
- Battery Charger Amps
396 (745)364 (687)
459 (858)413 (776)
3.9 (138)3.0 (105)
4.3 (151)3.2 (114)
10.2 (3.0)10.2 (3.0)
2027
1.40 (0.413)0.70 (0.207)
263-0765 (1)
Industrial
N/A
8.9 (2.4)
10.6 (2.8)
Spin-On, Full Flow
API CH4 15W-40
6.5 (1.7)6.5 (1.7)
Centrifugal
15.5 (881)
17.2 (978)
13.7 (779)
15.2 (864)
5.4 (307)4.8 (273)
6.3 (358)5.8 (330)
0.4 (0.5)0.2 (0.3)
41.4 (1462)33.0 (1165)
125 (0.5)125 (0.5)
1500 1800
Class A2 Diesel
Replaceable Element
4 / In Line
4 Stroke
84.0 (3.3)/100.0 (3.9)
Naturally Aspirated
Water
ISO 8528
Mechanical
23.3:1
2.2 (135.2)
2.72 (9308)
12/Negative
65
242 (534)
251 (554)
585.0 (84.8) 583.0 (84.6)
647.0 (93.8)649.0 (94.2)
19.4 (26.0)
21.5 (29.0)
16.2 (22.0)
18.0 (24.0)
3.1 (0.8)4.0 (1.1)5.2 (1.4)5.7 (1.5)
2.6 (0.7)3.4 (0.9)4.4 (1.2)4.8 (1.3)
3.3 (0.9)
2.7 (0.7)
4.4 (1.2)
3.7 (1.0)
5.7 (1.5)
4.8 (1.3)
Replaceable Element
1.7 (61)1.5 (51)
1.7 (61)1.5 (51)
3.0 (12.0)3.0 (12.0)