user manual

3
Electrical Configuration and Brewing Efficiency
US & Canada
CBS-2031e / CBS-2031s
3.0 liters per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 11)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E31045 1 X 1.5 KW 120 single 2 + ground 1.6 13.0 4.9 11.0
Can be connected
2 X 1.5 KW 120/208 single 3 + ground 2.4 11.3 7.3 11.0
to 120 VAC or
120/220 2.6 12.0 8.2 11.0
120/208-240 VAC
120/240 3.1 13.0 9.7 11.0
E31035 1 X 1.7 KW 120 single 2 + ground 1.8 14.7 5.5 11.0
Can be connected
2 X 1.7 KW 120/208 single 3 + ground 2.7 12.8 8.3 11.0
to 120 VAC or
120/220 3.0 13.5 9.2 11.0
120/208-240 VAC
120/240 3.5 14.7 11.0 11.0
E31015 1 X 2.3 KW 120 single 2 + ground 2.4 19.7 7.4 11.0
Can be connected
2 X 2.3 KW 120/208 single 3 + ground 3.6 17.1 11.0 11.0
to 120 VAC or
120/220 4.1 18.1 11.0 11.0
120/208-240 VAC
120/240 4.7 19.7 11.0 11.0
CBS-2032e / CBS-2032s 3.0 liters per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 22)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E32015 2 X 3 KW 120/208 single 3 + ground 4.6 22.4 14.6 22.0
120/220 5.1 23.7 16.9 22.0
120/240 6.1 25.8 19.4 22.0
* Based on standard factory settings: 4.0 minute brew time; 0% prewet; 200 F water.
Export
CBS-2031e / CBS-2031s
3.0 liters per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 11)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E31025 1 X 3 KW 220 single 2 + ground 2.6 12.0 8.4 11..0
CBS-2032e / CBS-2032s 3.0 liters per batch
Electrical Heater Voltage Maximum Batches per Hour* (max 22)
Config. Code Configuration (AC) Phase Wires KW Amp draw Cold Water Hot Water
E32025 2 X 3 KW 220 single 2 + ground 5.1 23.7 16.9 22.0
* Based on standard factory settings: 4.0 minute brew time; 0% prewet; 200 F water.