1. Summary of components
1−31
Festo P.BE−SPC200−EN en 0901d
1.7 I/O address range of the SPC200
A complete word (16 bit) for inputs and/or outputs is avail
able for every component and every I/O module, irrespective
of how many I/Os are integrated.
Configuring the SPC200
Maximum address range
without field bus module with field bus module
First I/O module I0.0...I0.9
1)
Q0.0 ... Q0.7
1)
I/O module on the first axis interface string I1.0...I1.15 Q1.0 ... Q1.15
Second I/O module First I/O module I2.0...I2.9 Q2.0 ... Q2.7
I/O modules on the second axis interface string I3.0...I3.15 Q3.0 ... Q3.15
Third I/O module Second I/O module I4.0...I4.9 Q4.0 ... Q4.7
Fourth I/O module Third I/O module I5.0...I5.9 Q5.0 ... Q5.7
Field bus module I10.0...I13.15
2)
Q10.0 ... Q13.15
2)
1)
Address range is not available if a field bus module is used
2)
Address range not available without a field bus module