User Manual
1. Summary of components
1−24
Festo P.BE−S PC200−EN en 0901d
1.4 Operating modes of the SPC200
The SPC200 offers suitable operating modes for the different
applications. The functions of the digital inputs and outputs
of the SPC200 depend on the operating mode set. The follow
ing operating modes are available:
Start/Stop mode
Record Select mode
Start/stop mode In Start/stop mode the SPC200 can control simple position
ing tasks independently or together
with a higher−order
PLC/IPC. Freely programmable inputs and outputs are avail
able in this operating mode.
You can start and stop positioning programs either with the
control panel, a handheld or a higher−order PLC/IPC.
The command Programmed Stop (M00) is available for loose
coupling with a higher−order PLC/IPC. With this command
you can synchronize
the program sequence of the SPC200,
e.g. with externally controlled processes.
Record Select mode The Record Select operating mode supports the close
coupling of the SPC200 with a higher−order PLC/IPC. The
complete sequence control here is carried out by the con
trolling PLC/IPC. This controller passes positioning tasks in
the form of record numbers via
digital I/Os to the SPC200.
When the I/O module is used, the NC records 0...31 of the
active program can be accessed via 5 digital inputs. These
records usually contain positioning tasks. The PLC/IPC can
therefore access freely up to 32 positions per axis. The maxi
mum permitted number of NC records (1000
NC records) can
be accessed via field bus modules.