User Manual
C. Technical appendix
C−25
Festo P.BE−SPC200−EN en 0901d
Type SPC200−DIO (PNP)
Temperature range
Operation
Storage/transport
− 5 ... + 50 °C
− 20 ... + 70 °C
Weight 62 g
Relative humidity 95 %, non−condensing
Digital inputs
Design
Logic level: ON
OFF
Current consumption (at 24V) (input current
from sensor to input)
Response delay (at 24 V)
Reference potential
10 inputs as per IEC 1131−2 type 2 inputs 24 V
DC positive−switching (PNP)
> 11 V
< 5 V
At logical 1"; typ. 8 mA
Typ. 5 ms
0 V
Digital outputs
Design
Load capacity per output
Electronic fuse (short circuit, overload)
Trigger current
Response time
8 outputs as per IEC 1131−2
24 V DC; positive−switching
250 mA
> 2 A
Max. 1.5 ms
Sensor supply V
D
24 V ± 25 % Max. 0.5 A (electronic short−circuit protection)
Electrical isolation
Inputs
Outputs
No
Yes
CE symbol (declaration of conformity)
è www.festo.com
In accordance with EU EMC Directive
Vibration and shock
Vibration
Shock
Tested as per DIN/IEC 68 part 2−6:
0.15 mm path at 10...58 Hz;
2 g acceleration at 58...150 Hz
Tested as per DIN/IEC 68 part 2−27:
± 30 g at 11 ms duration; 5 shocks per direction