User Manual

C. Technical appendix
C−11
Festo P.BE−SPC200−EN en 0901d
The following signal states must exist at the control inputs
before the readiness to operate can be created:
Record Select mode
Control input Signal
ENABLE 1−signal
STOP When acknowledging with the RES ET signal:
0−signal
When acknowledging with the CLK signal:
1−signal
RESET 0−signal
CLK_B 0−signal
CLK_A 0−signal
Tab.C/1: Necessary signal states in Record Select mode
Start/Stop mode
Control input Signal
ENABLE 1−signal
STOP 1−Signal
*)
START/RESET 0−signal
SYNC_IB not relevant
SYNC_IA not relevant
*)
If there is a 0−signal at the STOP input, a Program Reset will be
triggered by a rising edge at the START/RESET input.
Tab.C/2: Necessary signal states in Start/Stop mode