User Manual
C. Technical appendix
C−9
Festo P.BE−SPC200−EN en 0901d
C.1.3 Start program or NC record
Prerequisites
The program must already be saved in the program memory
The axis, application and system data must be set correctly
The operating mode must be set
The SPC200 is ready to operate (1−signal at ENABLE and STOP
inputs and at READY output)
Start NC program in Start/Stop mode
In the operating mode Start/Stop the sequence is started or
continued with a rising signal edge at the START input. There
must be a 1−signal here at the STOP input.
If there is a 0−signal at the STOP input, a Program Reset will
be triggered by a rising edge at the START input.
Set START
Reset START
Wait 10 ms
Process NC program in
Start/Stop mode
Prepare new start
NC program will be started
Debounce time
End
Fig.C/5: Start NC program in Start/Stop mode