User Manual

A. Notes on installing the pneumatic components
A−34
Festo P.BE−SPC200−EN en 0901d
Valve−drive combinations with DNCI−...
Recommendation: Use only suitable valve−drive combina
tions, see the following illustration.
1 Proportional
directional
control valve type
MPYE−5−...−010B
2 Drive diameter
3 Stroke length of
the drive
1
2
3
50 150 250 450 650 750350 550
32
40
50
63
MPYE−5−1/8HF−010B
MPYE−5−1/8LF−010B
MPYE−5−1/4−010B
L[mm]
[mm]
MPYE−5−M5−010B
Fig.A/24: Suitable valve−drive combinations with DNCI−...
The limits related to stroke length and valve types are to be
regarded as flowing. If you wish for a system with higher dy
namics, you should use the valve with the higher flow in the
limit range. If you attach great importance to control accu
racy, you
should use the valve with the lower flow, providing
this fulfills your requirements as regards the dynamics.