User Manual
A. Notes on installing the pneumatic components
A−20
Festo P.BE−SPC200−EN en 0901d
Installation instructions for standard cylinder type
DNCM−...−POT
Any mounting position is permitted (horizontal, vertical or
diagonal)
· Note that in conjunction with the SPC200, the complete
stroke of the drive must not be used.
Permitted work stroke = stroke length minus stroke
reduction
On each side of the drive positioning must not take place in
the range of the stroke reduction (see also chapter 3.4).
The best possible positioning
behaviour can be
achieved if you use only 80 % of the stroke length of
the drive, symmetrically to the two end positions.
If demands placed on the positioning behaviour are
o
nly slight, observe at least the following stroke re
ductions in both end positions:
Piston j [mm]
32 50
Stroke reduction per end position [mm] 10 15
· Drives with adjustable end position cushioning (PPV): In
order to use the end position cushioning as minimum
stop protection, tighten completely the adjusting screws
for the internal end position cushioning.
· Recommendation: Limit the positioning range by shock
absorbers, also in the case of a cylinder with adjustable
cushioning. In this way you can avoid damage in th
e
event of operating and system faults.
· Arrange the tubing between the valve (MPYE−5−...) and the
drive (DNCM−...) symmetrically and as short as possible.
Maximum tubing length = cylinder stroke length + 50 mm.