User Manual
A. Notes on installing the pneumatic components
A−12
Festo P.BE−SPC200−EN en 0901d
Valve−drive combinations with DNC−...
Recommendation: Use only suitable valve−drive combina
tions. The following diagram shows valve−drive combinations
for type DNC−... .
1 Proportional
directional
control valve type
MPYE−5−...−010B
2 Drive diameter
3 Stroke length of
the drive
1
2
3
50 150 250 450 650 750350 550
32
40
50
63
80
MPYE−5−1/8HF−010B
MPYE−5−1/8LF−010B
MPYE−5−3/8−010B
MPYE−5−1/4−010B
L[mm]
∅ [mm]
MPYE−5−M5−010B
Fig.A/10: Suitable valve−drive combinations with DNC−...
The limits related to stroke length and valve types are to be
regarded as flowing. If you wish for a system with higher dy
namics, you should use the valve with the higher flow in the
limit range. If you attach great importance to control accu
racy, you
should use the valve with the lower flow, providing
this fulfills your requirements as regards the dynamics.