A. Notes on installing the pneumatic components
A−4
Festo P.BE−SPC200−EN en 0901d
Valve−drive combination with DGP(L)−... and
DG PI(L)...
Recommendation: Use only suitable valve−drive combina
tions. The following diagram shows valve−drive combinations
for type DGP(L)−... and DGPI(L)... .
L[mm]
∅ [mm]
1
MPYE−5−3/8−010B
MPYE−5−1/4−010B
MPYE−5−1/8HF−010B
200 400 600 800 1000 1200 1400 1600 1800 2000
25
32
40
50
63
MPYE−5−1/8LF−010B
2
3
1 Proportional directional control valve
type MPYE−5−...−010B
2 Drive diameter
3 Stroke length of the drive
Fig.A/2: Suitable valve−drive combination with DGP(L)−... and DGPI(L)...
The limits related to stroke length and valve types are to be
regarded as flowing. If you wish for a system with higher dy
namics, you should use the valve with the higher flow in the
limit range. If you attach
great importance to control accu
racy, you should use the valve with the lower flow, providing
this fulfills your requirements as regards the dynamics.