User Manual

A. Notes on installing the pneumatic components
A−4
Festo P.BE−SPC200−EN en 0901d
Valve−drive combination with DGP(L)−... and
DG PI(L)...
Recommendation: Use only suitable valve−drive combina
tions. The following diagram shows valve−drive combinations
for type DGP(L)−... and DGPI(L)... .
L[mm]
[mm]
1
MPYE−5−3/8−010B
MPYE−5−1/4−010B
MPYE−5−1/8HF−010B
200 400 600 800 1000 1200 1400 1600 1800 2000
25
32
40
50
63
MPYE−5−1/8LF−010B
2
3
1 Proportional directional control valve
type MPYE−5−...−010B
2 Drive diameter
3 Stroke length of the drive
Fig.A/2: Suitable valve−drive combination with DGP(L)−... and DGPI(L)...
The limits related to stroke length and valve types are to be
regarded as flowing. If you wish for a system with higher dy
namics, you should use the valve with the higher flow in the
limit range. If you attach
great importance to control accu
racy, you should use the valve with the lower flow, providing
this fulfills your requirements as regards the dynamics.