Fault class 8: NC Editor, Upload/download or operation execution fault
Fault
stage
Eliminating faultsOperating status / fault explanationFault
message
D zzz16x08 Compatibility error between WinPISA and the
operating system version of the SPC200.
zzz = 001: The function Calibration of
operating system version 4.82
requires at least WinPISA 4.41.
· Use the latest version of
WinPISA; if necessary down
load it from Festo’s down
load area < festo.com> and
use it to carry out the
calibration.
· Adapt measuring system
length in the Axis data"
dialogue.
zzz = Additional information
yy = Fault number
x = Axis identifier (0 = fault is not axis−related)
ppp = Program number
Fault class 9: Trace fault
Fault
stage
Fault
message
Operating status / fault explanation Eliminating faults
D
00001x09 Too many trace variables defined.
Max. 10 trace variables per axis are
permitted
· Check measured value
configuration
00002x09
to
00005x09
Reserved
00006x09 Trace memory reserved for another
axis
· Create default measured value con
figuration for all axes. Then specify
desired configuration again
00007x09 Unknown trace variable defined
(caused by the use of different
firmware versions)
· Create and confirm default
measured value configuration.
Then set the desired configuration
again
00008x09 Trace not configured · Carry out System Reset
zzz = Additional information
yy = Fault number
x = Axis identifier (0 = fault is not axis−related)