Fault class 7: Fault in the pre−parametrizing
Fault
stage
Fault
message
Operating status / fault explanation Eliminating faults
C
00001x07 Software end position lies outside the
possible positioning range
· Correct parameter
(permitted value ranges see
chapter 6 2)
00002x07 Mass load lies outside the permitted range
chapter 6.2)
00003x07 Gain factor not permitted
00004x07 Damping factor not permitted
00005x07 Filter factor not permitted
00006x07 Measuring system length not valid or
measured value outside the set cylinder
length
00007x07 Parameter limit violated
00008x07 Measuring system type not permitted
00009x07 Reserved
0000Ax07 Max. permitted step frequency (positioning
frequency) exceeded (>40000 Hz)
· Check resolution or reduce
positioning speed
0000Bx07 Reserved
0000Cx07 Adaptation data incorrect · Carry out Data Reset
zzz = Additional information
yy = Fault number
x = Axis identifier (0 = fault is not axis−related)