User Manual
8. Diagnosis and error treatment
8−10
Festo P.BE−S PC200−EN en 0901d
Fault class The fault class reflects the type of fault which has occurred
(e.g. hardware fault, configuration fault etc.) as well as the
time the fault occurred. If the SPC200 is ready for communi
cation, the ERROR−LED will flash according to the fault class.
Fault time
Fault
class
Description
Initialization phase
1 Faults in initializing the components and modules
2 Reserved
3 User data damaged
Operating phase 4 Hardware fault in the operating phase
5 Sequence control fault (e.g. due to fault in the NC program)
Operating or commis
sioning phase
6 Fault in positioning task or identification travel
Commissioning phase 7 Fault in pre−parametrizing
8 NC Editor, Upload/download or operation execution fault
9 Trace fault