User Manual
4. Commissioning
4−21
Festo P.BE−SPC200−EN en 0901d
4.3.4 Application data of an electric stepping motor axis
The application data describe the general conditions under
which the positioning axis is operated:
Application data
Unit Default values Example
Resolution for a full step [1/1]
1)
mm
−1
5.00000 8.00000
Step mode
2)
1/2 1/1
Resolution
3)
mm
−1
10.00000 8.00000
Start−stop frequency Hz 400 400
Project zero point mm 0.00 0.00
Lower software end position mm 10.00 10.00
Upper software end position mm 90.00 490.00
Reference position mm 10.00 10.00
Reference speed factor 0.5 1.0
Maximum speed m/s 0.10 1.0
Maximum acceleration m/s
2
0.50 2.0
Reference run mode
1)
1 1
1)
Corresponds to Resolution" on the control panel
2)
Only limited availability via control panel
3)
Operand = resolution for full step divided by the step mode