4.3.1 Pneumatic axis data
The axis data describe all characteristics of the selected
drive, including the measurement system and the selected
valve.
Axis data
Unit Default values Example
Cylinder
Designation
1)
DGPIL−50−1000
Design Without piston rod Without piston rod
Length mm 100 1000
Diameter mm 25 50
Measuring system
Design
1)
Potentiometer Temposonic
Length mm 100 1000
Valve
Type MPYE−5−1/8−HF−010B MPYE−5−1/4−010B
Flow factor
1)
1
2)
1
2)
1)
Not available via control panel
2)
Value=1 means: optimal flow characteristics, no reduction due to angled connectors,
very thin hoses.