4. Commissioning
4−15
Festo P.BE−SPC200−EN en 0901d
Switch on the power supply
Warning
Leave the compressed air supply switched off. If com
pressed air is applied, the connected actuators may carry
out sudden compensating movements as soon as the
power supply is switched on.
Make sure that nobody can place his/her hand in the posi
tioning range of the moveable mass and that there are no
objects in its path.
Please note
If you are using control panel type SPC200−MMI−1F:
When the MMI−1F is switched on, it tries to communicate
with the SPC200. The SPC200 must therefore be ready for
communication.
Switch on the power supplies for the SPC200 and the
MMI−1F therefore either simultaneously or in the following
sequence:
1. first the power supply for
the SPC200
2. then the power supply for the MMI−1F.
· Switch on the operating voltage and the load voltage for
the SPC200 and, if necessary, the operating voltage for
the control panel type S PC200−MMI−1F.
When the power supply is applied, the SPC200 automatically
performs an internal test. If the control panel is inserted, it
will display the current fault number in the event
of a fault
(see section 8.2). When the device is switched on the first
time, the following fault code will be displayed.
ERROR
no. 00004001