User Manual
3. Installation
3−46
Festo P.BE−S PC200−EN en 0901d
General connection assignment for I/O modules
without special control functions
The word number (here x) depends on the configuration of
the SPC200.
Configuration without
field bus module
Configuration with
field bus module
Word
number x
Second I/O module First I/O module 2
Third I/O module Second I/O module 4
Fourth I/O module Third I/O module 5
Outputs without control function
Pin no. Design.
1)
Address
2)
Start/Stop mode Record Select mode
3)
1 0 Qx.0
Freely programmable
2 1 Qx.1
3 2 Qx.2
4 3 Qx.3
5 4 Qx.4
6 5 Qx.5
7 6 Qx.6
8 7 Qx.7
9 24 V 24 V external supply of outputs
10 0 V 0 V external supply of outputs
1)
Designation on the module
2)
The word number (here x) depends on the configuration (Q = output).
3)
No freely programmable I/Os are supported in this operating mode.