User Manual

3. Installation
3−45
Festo P.BE−SPC200−EN en 0901d
General connection assignment for I/O modules
without special control functions
The word number (here x) depends on the configuration of
the SPC200.
Configuration without
field bus module
Configuration with
field bus module
Word
number x
Second I/O module First I/O module 2
Third I/O module Second I/O module 4
Fourth I/O module Third I/O module 5
Inputs without control function
Pin no. Design.
1)
Address
2)
Start/Stop mode Record Select mode
3)
1 24 V 24 V sensor supply (not with separate potential)
2 0 V 0 V (not with separate potential)
3 0 Ix.0 Freely programmable
4 1 Ix.1
5 2 Ix.2
6 3 Ix.3
7 4 Ix.4
8 5 Ix.5
9 6 Ix.6
10 7 Ix.7
11 8 Ix.8
12 9 Ix.9
1)
Designation on the module
2)
The word number (here x) depends on the configuration (I = input).
3)
No freely programmable I/Os are supported in this operating mode.