User Manual

3. Installation
3−44
Festo P.BE−S PC200−EN en 0901d
Connection assignment of front plug X6 for the first
I/O module when operated without a field bus
module
If a field bus module is not installed, the first I/O module will
provide the following control outputs:
Outputs with control function
Pin no. Design
1)
Address
2)
Start/Stop mode Record Select mode
3)
1 0 Q0.0
Freely programmable
2 1 Q0.1
3 2 Q0.2
4 3 Q0.3 MC_B RC_B
5 4 Q0.4 MC_A RC_A
6 5 Q0.5 SYNC_OB ACK_B
7 6 Q0.6 SYNC_OA ACK_A
8 7 Q0.7 READY READY
9 24 V 24 V external supply of outputs
10 0 V 0 V external supply of outputs
1)
Designation on the module
2)
Addresses of the first installed I/O module when configured without a field bus module
(Q = output)
3)
No freely programmable I/Os are supported in this operating mode.