User Manual

3. Installation
3−38
Festo P.BE−S PC200−EN en 0901d
3.5.4 Connections of the I/O module type SPC200−DIO−...
For controlling the SPC200 via digital I/Os, you will require
anI/O module type SPC200−DIO−.... This module provides
10digital inputs and 8 digital outputs for the following func
tions:
providing digital I/Os for controlling the SPC200 (only if
no field bus module is installed)
providing freely programmable digital I/Os for controlling
peripherals.
Please note
Maximum three I/O modules are permitted for operation
on the field bus. Without a field bus module, four I/O mod
ules can be installed in a rack.
The logical functions of the digital inputs/outputs depend on
the operating mode selected. Freely programmable I/Os are
only available in Start/stop mode.
Control via digital
I/Os of the I/O module is only possible if a
field bus module is not installed. Identification of all inserted
modules takes place automatically, from left to right begin
ning with the power supply module. The assignments of plug
X5/X7 (inputs) and of plug X6/X8 (outputs) are shown in the
following diagrams.