4.2 Connecting the measuring system
S Connect the measuring system cable of the drive with
the m
easuring system connection of the axis interface.
Please note
Connect only the original measuri ng system. Use only
the original cable. Do not extend the cable. Use the
short cable length to avoid interference
from electro
magnetic sources.
Pin
Designation Pin assignment
1 5 V sensor supply
7
2 GND
1
6
3 Signal sinus +
5
8
4 Signal sinus
4
2
5 Signal cosinus
3
6 Signal cosinus +
7 Screening
8 n. c.