5 Fitting
Mechanical fitting
S Prevent the sealing band from being
pressed or sucked in.
Damage to the sealing band reduces the
operating reliability.
A sudden jerk movement of the pressure
less slide can create a low pressure which sucks the sealing band into the
piston chamber.
S Place the component in position
with re
gard to the following points:
You must be able to gain access to the
operating parts and connections later
when the component is installed.
The fitting position takes into account
the minimum distances required for
reliable operation of the proximity
switches used.
L
1
L
2
= L
3
L
4
L
5
(SME−1 0−...) (SMT−10−...)
L
1
L
5
SLG−8−... as desired 10 mm 17 mm 4 mm
SLG−12−... 12 mm as desired
SLG−18−... 46 mm 26 mm
Fig.8
If the minimum distances are not observed, an individual functional check may
be necessary.
Fig.6
Fig.7