2. Assembly
2−21
Festo P.BE−CPX−SYS−EN en 0902e
2.4 Fitting the CPX terminal
Note
Fit the CPX terminal so that there is sufficient space for
heat dissipation and ensure that the maximum limits for
temperatures are observed (see Technical data).
You can fit the CPX terminal in one of two ways:
Mounting method Description
H−rail mounting The CPX terminal is suitable for fitting onto an H−rail (mounting rail as
per EN60715). There is a guide groove on the back for hanging the
valve terminal onto the H−rail.
Wall mounting The end plates and the pneumatic interface contain holes for fitting
the terminal onto a wall. CPX terminals with four or more interlinking
blocks require additional mounting components for the electric
modules.
Tab.2/2: Methods of fitting the CPX terminal
2.4.1 Fitting CPX terminals without pneumatics onto a H−rail
For fitting the CPX terminal without pneumatics onto an H−rail,
you will require mounting kit type CPA−BG−NRH. This kit con
tains 2clamping components and 2M4x12 screws.
Fitting onto an H−rail is carried out in the same manner as
fitting CPX terminals with pneumatics onto an H−rail (see sec
tion2.4.2).