Instruction Manual
1. Overview of components
1−21
Festo P.BE−CPX−SYS−EN en 0902e
Interlinking blocks
M18 or 7/8"
Description
Types CPX−(M−)GE−EV−S...
Interlinking blocks in plastic and metal version with system supply, of
which precisely one of each must be available for each CPX terminal.
Operating voltage for internal electronics and for the internal electronics
of the CP modules connected to the CPX−CP interface
Sensor supply for internal input modules and for the CP input modules
connected to the CPX−CP interface
Load voltage supply for internal output modules and valves
Load voltage supply for the CP modules connected to the CPX−CP inter
face
Types CPX−(M−)GE−EV−Z...
1)
Interlinking blocks in plastic and metal version with additional power
supply for electrical outputs
Load voltage supply for the output module inserted and for the
subsequent output modules inserted to the right.
Type CPX−GE−EV−V...
1)
2)
Interlinking blocks with additional power supply for valves
Load voltage supply for the pneumatic modules/valves inserted
subsequently to the right.
Load voltage supply for CP modules which are connected to the fitted
CPX−CP interface and to those CPX−CP interfaces subsequently fitted to
the right
1) Optional − depends on the current consumption of the CPX modules and the connected compo
nents.
2) Not available for all alternative connections.
Tab.1/5: Interlinking blocks with supply (M18 or 7/8")