Instruction Manual

B. Parameters and data of the CPX terminal
B−26
Festo P.BE−CPX−SYS−EN en 0902e
Diagnostic memory parameter: Fault end filter
Function no. 3484
Description Diagnostic memory filter with which you can determine whether running faults
are to be registered or not.
Bit Bit 3
Values
Bit 3
0
1
Fault end filter
Description
Register running faults (end of fault) (filter inactive,
presetting)
Do not register running faults (end of fault) (filter
active)
[Fault end filter]
[Rec. outg. faults]
[Do not rec. outg. faults]
Note By registering the outgoing fault, you can ascertain how long the fault has
existed. Incoming and running faults each represent one entry. With running
faults the fault number 0" is entered. Maximum 40 entries are saved together.
Tab.B/27: Fault end filter
Diagnostic memory parameter: Error number filter
Function no. 3484
Description With this diagnostic memory filter you can:
Suppress the registering of a desired fault message
Register exclusively a desired fault message
Bit Bits 4, 5
Values
Bit 5 4
00
01
10
11
Error number filter
FN = error number
Description
Error number filter inactive (presetting)
Register only defined FN
Do not register defined FN
Reserved
[Fault numbers filter]
[Inactive]
[Rec. only def. FN]
[Do not rec. def. FN]
Note The error number is determined by means of the diagnostic memory parameter
Error number" (function no. 3487).
Tab.B/28: Error number filter