Instruction Manual

B. Parameters and data of the CPX terminal
B−24
Festo P.BE−CPX−SYS−EN en 0902e
Diagnostic memory parameters: Entries remanent with Power on
Function no. 3480
Description Determines whether the contents of the diagnostic memory are to be retained
after new Power on or whether they are to be deleted.
Bit 0 Entries remanent with new power ON [Entries remanent at
Power ON]
Values 1 = inactive
0 = active (presetting)
[Inactive]
[Active]
Note The diagnostic memory will be deleted if the mode is changed.
Tab.B/24: Entries remanent with Power on
Diagnostic memory parameter: Run/stop filter 1
Function no. 3480
Description Diagnostic memory filter with which you can determine whether the first
40 errors or the last 40 errors are to be saved.
Bit Bit 1
Values
Bit 1
0
1
Run/stop filter 1:
Save the first 40 entries (stop after 40 entries);
Save the last 40 entries (overwrite old entries, pre
setting)
[Run/Stop 1]
[Save the first 40 entries]
[Save the last 40 entries]
Note The diagnostic memory will be deleted if the mode is changed.
Tab.B/25: Run/stop filter 1