User guide
5. Parameter
5−28
Festo P.BE−CPX−CMAX−CONTROL−EN en 0908NH
Manufacturer device name
PNU PNU: 120 Index: 1 ... 30 Max index: 30 Class: Array Data type: char
Values Default: CPX−CMAX−C1−1
Impermissible characters: −
CMAX designation (type). Unused characters are filled with zero (=00h=’0’).
ý The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.
User device name
PNU PNU: 121 Index: 1 ... 30 Max index: 30 Class: Array Data type: char
Values Default: CMAX0001
Impermissible characters: ? @ . , ! : " § | $ % & / # ‘ ’ + ~ * ’ ; ° ^ < >
CMAX designation defined by the user. The name serves the identification by FCT and is checked by
the FCT when the connection to the device is established.
Example: CMAX1_Slot3". Unused characters are filled with zero (=00h=’0’).
The CMAX also contains an axis name (PNU 180 ff) along with the device name.
o The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
ý This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.
Drive manufacturer
PNU PNU: 122 Index: 1 ... 30 Max index: 30 Class: Array Data type: char
Values Default: Festo AG & Co. KG
Impermissible characters: −
Controller manufacturer’s name Unused characters are filled with zero (=00h=’0’).
ý The parameter value cannot be changed.
o Writing permissible only in commissioning/parametrising mode with disabled controller.
o This parameter can be written by FCT without higher−order controller.
o After writing, controller recalculation is carried out.