User guide

4. Faults and diagnostics
4−14
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
Fault group 2 record error
CPX error group 102 (CPX−MMI: [Record error] )
No. Message Cause/description Error handling Type
1)
21 Impermissible record
number
When starting an invalid
record number was
pending (0 or > 64).
· Check record
numbers and correct
(first transfer record
number, then starting
edge).
Level: F1
Reset: R
Info: x
22 Record is not configured Retrieved record was
not configured and con
tains no valid position
ing data.
· Check record and
parametrise.
Level: F1
Reset: R
Info: x
23 Record is blocked The retrieved record is
not enabled for execu
tion.
· Check and enable
record.
Level: F1
Reset: R
Info: x
24 Record sequencing is
not permissible
The demanded sequenc
ing condition is invalid.
· Check and correct the
sequencing condi
tion.
Level: F1
Reset: R
Info: x
Sequencing parame
trised in record 64.
· Remove sequencing
condition in record
64, correct record list
if necessary
The selected sequenc
ing condition is not per
missible when using a
DSMI. The DSMI does
not support force con
trol.
· Correct sequencing
condition
The selected sequenc
ing condition is only per
missible in a record with
force control.
· Check and correct
record.
1)
Level: fault level, see section 4.2.3
Reset: behaviour upon reset, see section 4.2.4
Info: = no info; x = additional info, see FCT or section 4.3.3