User guide
4. Faults and diagnostics
4−3
Festo P.BE−CPX−CMA X−CONTROL−EN en 0908NH
4.1 Overview of diagnostics options
The CMAX supports a number of different options for diag
nostics and error handling in the CPX terminal.
An overview is shown in Tab.4/1.
Access/
Function
Diagnostics
option
Brief description Detailed
description
Local
Display on the
device
LED display, dis
play / 7−
segment display
The LEDs and the display directly indi
cate operating and fault statuses.
Fast on−the−spot" diagnosis.
CMAX system
description
CPX−MMI The CPX−MMI can be used to display the
CPX module diagnosis
1)
.
Description of the
CPX−MMI
Local
with PC (e.g.
during startup)
FCT with CMAX
plug−in
Plain−text display of all diagnostic in
formation during startup and servicing.
Full access to the diagnostic functional
ity of the CMAX.
Help for the CMAX
FCT PlugIn
CPX−FMT The CPX−FMT can be used to display the
CPX module diagnosis
1)
.
Help for the CPX−FMT
PLC
via I/O data
Module output
and input data
Diagnostic information is constantly
transferred in the SCON status byte
(e.g. actual values, WARN and FAUL T
bits etc.). Direct access to the status
(e.g. current position) and diagnostic
status via the CPX node.
Section 2.2
CPX status bits,
I/O diagnostic
interface
The CPX module diagnosis
1)
is reported
to the CPX node Optimum integration
into the CPX module concept.
Section 4.5
PLC
via communi
FHPP diagnostics
Diagnostic parameters Section 4.3
v
i
a commun
i
cations profile
Diagnostic memory Section 4.3.2
1)
The CPX diagnostics only show the fault groups of the CMAX.
Tab.4/1: Diagnostics options